+91-731-2857347     +91-8827916878

EP24H10 Electroplating Power Source

Parameter Value
Input voltage 415Vac ± 10%, 50 Hz,
Input power factor 0.93
Output voltage 0.5V – 24 V variable (under 5% or more loaded condition)
Output current 30-1000A @ rated load resistance
Voltage regulation < 0.5%
Current regulation < 0.5%
Duty cycle Continuous
Protections Line Over Voltage, and Output Over Current, Over Temperature
Ripple factor < 2% at full load
Current/Voltage stability 0.5% for ambient temperature of 35 deg centigrade after 1 hour of operation
Current monitoring 3 ½ digit DPM
Voltage Monitoring 3 ½ digit DPM
Cooling Forced air cooling
Size 650 mm (W) x 400mm (H) x 480 mm(D)
Weight 45 kg